Dual chemical bonding construction of electrochemical peptide sensor based on GDY/MOFs(Fe) composite for ultra-low determination of prostate-specific antigen

A novel “double chemical bonding” electrochemical peptide biosensor 2FcP-GA-GDY(Fe)@NMIL-B was developed for highly selective, ultrasensitive, and ultrastable identification of prostate-specific antigen (PSA). The C–Fe–O chemical bond linking Fe-Graphdiyne (Fe-GDY) with NH2-MIL88B(Fe) (NMIL88B) as t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2024-10, Vol.278, p.126459, Article 126459
Hauptverfasser: Ren, Yaofei, Li, Jialing, Wu, Weixuan, Yu, Xin, Tao, Mengying, Han, Yanhu, Lin, Yintong, Shi, Zhongfeng, Zhou, Liqin, Zhao, Zhenxia, Zhao, Zhongxing
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A novel “double chemical bonding” electrochemical peptide biosensor 2FcP-GA-GDY(Fe)@NMIL-B was developed for highly selective, ultrasensitive, and ultrastable identification of prostate-specific antigen (PSA). The C–Fe–O chemical bond linking Fe-Graphdiyne (Fe-GDY) with NH2-MIL88B(Fe) (NMIL88B) as the first chemical bonding of electrode carrier Fe-GDY@NH2-MIL88B(Fe) (GDY(Fe)@NMIL) significantly accelerates electron transport. With glutaraldehyde (GA) as a crosslinking agent, the Schiff-base –NC- formed by GDY(Fe)@NMIL nanocomposites links the two Fc molecules labeled peptides (2FcP) as the second chemical bonding, facilitating high-density attachment of peptides to the electrode carrier in a firm manner. When the PSA analyte is introduced to identify and cleave the specific peptide, the release of ferrocene from its head leads to a decrease in the electrical signal, enabling sensitive detection. The prepared sensing platform exhibits exceptional analytical performance for PSA with an extended linear response range from 10 fg mL−1 to 50 ng mL−1. Additionally, the detection limit has been significantly reduced to an ultra-low level of only 0.94 fg mL−1, surpassing those reported in most literature by several orders of magnitude. Moreover, the 2FcP-GA-GDY(Fe)@NMIL-B sensor has excellent selectivity and stability while also showcasing great potential for practical application of PSA detection in human serum using the standard addition method. [Display omitted] •Electrochemical peptide sensor with dual chemical bonding for PSA detection.•The first chemical bonding C–Fe–O accelerate electron transport of sensor.•The second chemical bonding –NC- enhance detection stability and sensitivity.•Detection limits about 3 orders of magnitude lower than other biosensors.•The sensor shows a wide linear range of 10 fg mL−1 to 50.0 ng mL−1
ISSN:0039-9140
1873-3573
1873-3573
DOI:10.1016/j.talanta.2024.126459