Influence of different palatal morphologies on the accuracy of intraoral scanning of the edentulous maxilla: A three-dimensional analysis

Purpose: This study investigated the influence of different palatal morphologies on the accuracy of intraoral scanning (TRIOS 4) of edentulous maxillae.Methods: Six typodonts were fabricated for different palatal morphologies with flat (F), medium (M), and deep (D) palates, with palatal wrinkles (W)...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Prosthodontic Research 2024, Vol.68(4), pp.634-642
Hauptverfasser: Sorrentino, Roberto, Ruggiero, Gennaro, Leone, Renato, Mauro, Maria Irene Di, Cagidiaco, Edoardo Ferrari, Joda, Tim, Russo, Lucio Lo, Zarone, Fernando
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose: This study investigated the influence of different palatal morphologies on the accuracy of intraoral scanning (TRIOS 4) of edentulous maxillae.Methods: Six typodonts were fabricated for different palatal morphologies with flat (F), medium (M), and deep (D) palates, with palatal wrinkles (W), or smooth palates (S), resulting in six groups: WF, WM, WD and SF, SM, SD. Ten scans were performed for each group; standard tessellation language files obtained were imported into a software to measure trueness and precision in micrometer. Trueness was calculated as the mean of the standard deviation values obtained by superimposing each scan onto the reference scan. Precision was achieved by overlapping each scan with that with the best trueness in the group. Descriptive and post-hoc analyses were conducted.Results: The mean values for trueness were as follows: WM=48.7±4.7, WD=161.7±18.4, WF=85.9±16, SM=48.1±2.4, SD=349.9±8.8, and SF=349.1±25.5. The precision values were as follows: WM=46.7±7.3, WD=46.9±9, WF=48.9±6.7, SM=46±2.7, SD=105.9±17.4, SF=72.6±10.8. Significant differences were observed for trueness between SM and SD (P < 0.001), SM and SF (P < 0.001), and WF and SF (P = 0.003); whereas for precision, significant differences were reported between WD and SD (P = 0.015). Regarding trueness and precision, no difference was found between WM and SM (P = 1.0).Conclusions: Medium palatal depth showed the best accuracy. The mean accuracy values were within the clinical acceptability thresholds for all palatal morphologies. The presence of rugae improved the precision of deeper palates and the trueness of flat palates. No differences were observed in the medium palates with or without rugae.
ISSN:1883-1958
2212-4632
1883-9207
2212-4632
DOI:10.2186/jpr.JPR_D_23_00175