A Comparative Analysis of Two Commonly Used FDA-Approved Immunoassays for Fentanyl Detection

Abstract Background Given the opioid epidemic, fentanyl screening in urine has become increasingly important. Immunoassays remain the most common screening methodology due to the high throughput and ease of integration into automated chemistry systems. The fentanyl ARK II from Ark Diagnostics is a w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The journal of applied laboratory medicine 2024-09, Vol.9 (5), p.905-912
Hauptverfasser: Lam, K H Brian, Menlyadiev, Marlen, Buggs, Vincent, Parnprome, Suttida, Pesce, Amadeo, Suhandynata, Raymond T, Fitzgerald, Robert L, Song, Lu, Metushi, Imir G
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Given the opioid epidemic, fentanyl screening in urine has become increasingly important. Immunoassays remain the most common screening methodology due to the high throughput and ease of integration into automated chemistry systems. The fentanyl ARK II from Ark Diagnostics is a widely used immunoassay, while a novel fentanyl assay called FEN2 by Lin-Zhi has become available on the Roche platform. Here, we evaluate and compare their performance. Methods Four hundred and thirty-four urine samples were analyzed for fentanyl across the Lin-Zhi FEN2 and ARK II assays on the Cobas c502 platform. Samples were analyzed immediately upon request for drug of abuse screening or frozen for subsequent analysis. For confirmation testing, a liquid chromatography–tandem mass spectrometry (LC-MS/MS) method with a limit of detection of 1 ng/mL for fentanyl/norfentanyl was used. Any sample with either fentanyl or norfentanyl above the LC-MS/MS cutoff was deemed positive. Results The ARK II had 11 false negatives and 7 false positives, while the Lin-Zhi FEN2 had 12 false negatives and 2 false positives. This resulted in ARK II having a sensitivity and specificity of 90.4% and 97.8% respectively, while Lin-Zhi FEN2 had a sensitivity and specificity of 89.5% and 99.4%. Conclusions Both the ARK II and Lin-Zhi FEN2 immunoassays detected fentanyl well. Overall, the Lin-Zhi assay had slightly better specificity than ARK II, in our data set. While some discrepant results were observed between the 2 immunoassay systems, most occurred near the immunoassay detection cutoffs.
ISSN:2576-9456
2475-7241
2475-7241
DOI:10.1093/jalm/jfae049