Mid-infrared optical coherence tomography with a stabilized OP-GaP optical parametric oscillator
We demonstrate mid-infrared time-domain optical coherence tomography (OCT) with an orientation-patterned GaP optical parametric oscillator. Instantaneous broadband mid-infrared spectra provide reduced scattering for OCT applications including cultural heritage, quality assurance, and security. B-sca...
Gespeichert in:
Veröffentlicht in: | Optics letters 2024-06, Vol.49 (11), p.2882 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We demonstrate mid-infrared time-domain optical coherence tomography (OCT) with an orientation-patterned GaP optical parametric oscillator. Instantaneous broadband mid-infrared spectra provide reduced scattering for OCT applications including cultural heritage, quality assurance, and security. B-scan calibrations performed across the wavelength tuning range show depth resolutions of 67 µm at 5.1 µm and 88 µm at 10.5 µm. Volumetric imaging inside a plastic bank card is demonstrated at 5.1 µm, with a 1 Hz A-scan rate that indicates the potential of stable broadband OPO sources to contribute to mid-infrared OCT. |
---|---|
ISSN: | 0146-9592 1539-4794 1539-4794 |
DOI: | 10.1364/OL.520734 |