Combination of headspace single-drop microextraction (HS-SDME) with a nickel-embedded paper-based analytical device for cyanide quantification
Cyanide anion can be found in foodstuffs, tobacco smoke and a variety of types of waters, mainly originating from anthropogenic activities. Due to its highly toxic nature, several agencies have established limits for cyanide levels in water. Additionally, monitoring cyanide levels in biological samp...
Gespeichert in:
Veröffentlicht in: | Analytica chimica acta 2023-11, Vol.1281, p.341882-341882, Article 341882 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Cyanide anion can be found in foodstuffs, tobacco smoke and a variety of types of waters, mainly originating from anthropogenic activities. Due to its highly toxic nature, several agencies have established limits for cyanide levels in water. Additionally, monitoring cyanide levels in biological samples, such as blood and urine, is crucial for obtaining clinical information about the health condition of patients. Therefore, there is a pressing need for the development of simple, cost-effective, and reliable analytical methods capable of quantifying cyanide at low concentrations.
This study presents a novel analytical method for the selective and sensitive determination of cyanide based on analyte volatilization, pre-concentration via single-drop microextraction (SDME) using a selective reagent, and colorimetric quantification using a paper-based analytical device. For this, 10 mL of a liquid sample was acidified with phosphoric acid and the generated HCN was collected using a single drop of 3 μL of a palladium dimethylglyoximate solution (Pd (DMG)22−) positioned in the flask headspace using a syringe. The reaction of Pd (DMG)22− leads to the formation of Pd(CN)42− and the demasking of the organic ligand. After 15 min of extraction time, the reagent drop was added to a paper-based analytical device that has been previously impregnated with 3 μL of nickel chloride, resulting in the formation of a red precipitate of nickel (II) dimethylglyoximate. Digital images of the paper-based device were captured and the red channel (R) was used for quantification purposes. Under optimized conditions, the method demonstrates a suitable linear relation (r2 > 0.99) ranging from 26 to 286 μg L−1 and a limit of detection of 5 μg L−1.
As a proof of concept, cyanide levels were quantified in water and urine samples using this method. The proposed approach offers high sensitivity and selectivity while requiring only a small volume of reagents. Furthermore, it exhibits a high degree of portability for in-situ applications.
A selective and sensitive method for the determination of cyanide using HS-SDEM. [Display omitted]
•Cyanide in liquid samples was determined by combining HS-SDME and digital image analysis.•Colorimetric reaction is performed on a microfluidic paper-based analytical device.•The reagent is easy to prepare and highly selective for cyanide.•Under optimized conditions, a limit of detection of 5 μg L-1 was achieved.•The point-of-care device is suitable for cyanide de |
---|---|
ISSN: | 0003-2670 1873-4324 |
DOI: | 10.1016/j.aca.2023.341882 |