The incidence of hypoxemia in dogs recovering from general anesthesia detected with pulse-oximetry and related risk factors

The postoperative period is critical for the development of complications, including hypoxemia. To detect hypoxemia early and provide appropriate care, continuous monitoring of saturation is necessary: pulse oximetry is an easily accessible and simple method for this purpose. However, a SpO2 cut-off...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The veterinary journal (1997) 2024-06, Vol.305, p.106135, Article 106135
Hauptverfasser: Piemontese, C., Stabile, M., Di Bella, C., Scardia, A., Vicenti, C., Acquafredda, C., Crovace, A., Lacitignola, L., Staffieri, F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The postoperative period is critical for the development of complications, including hypoxemia. To detect hypoxemia early and provide appropriate care, continuous monitoring of saturation is necessary: pulse oximetry is an easily accessible and simple method for this purpose. However, a SpO2 cut-off value to detect hypoxemia in dogs recovering from general anesthesia is lacking in the veterinary literature. The objectives of this clinical study are to validate the room air SpO2 test (SpAT), to identify a cut-off value to discriminate hypoxemia (Phase 1), and to apply the SpAT to study the incidence of transient postoperative hypoxemia (TPH) (Phase 2) in dogs with healthy lungs recovering from general anesthesia. Phase 1: 87 dogs recovering from general anesthesia with an arterial line were included. After extubation, SpAT was performed simultaneously with arterial blood sampling. A PaO2 < 80 mmHg was considered hypoxemia. Phase 2: 654 dogs were enrolled. They underwent general anesthesia with different ventilation settings for different procedures. After extubation, dogs were classified as hypoxemic if the SpO2 was lower than the cut-off obtained in phase 1. Phase 1 showed that the SpO2 cut-off is < 95% (sensitivity 100%, specificity 97.4%; area under the curve, AUC = 0.996; 95% Confidence Interval = 0.944–1; P 3/5, dorsal recumbency, FiO2 1, absence of Positive End-Expiratory Pressure (PEEP) had a significant odds ratio to induce TPH (5.8, 1.9, 3.7, 1.7, respectively). These results showed that SpO2 < 95% indicates PaO2 < 80 mmHg in dogs and TPH occurs in up to 28% of cases. Identification of associated risks could be useful to prevent and to increase awareness for monitoring and treatment. •Pulse oximetry is a reliable method for early detection of hypoxemia.•SpO2 < 95% while breathing room air is the cut-off value to identify a PaO2 < of 80 mmHg.•Transient Postoperative Hypoxemia (TPH) is an event occurring in up to 28% of dogs undergoing general anesthesia.•Risk factors for TPH are dorsal recumbency, BCS > 3 and a ventilatory setting with high FiO2 (1) and/or absence of PEEP.
ISSN:1090-0233
1532-2971
1532-2971