Leadless pacemakers offer the opportunity to avoid transvenous hardware among patients with tricuspid valve prostheses. We present the first case of a helix-based fixation leadless pacemaker implanted through valve-in-valve tricuspid prostheses in a 43-year-old female with extensive prior cardiac hi...
Gespeichert in:
Veröffentlicht in: | Journal of interventional cardiac electrophysiology 2024-08, Vol.67 (5), p.915-917 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Leadless pacemakers offer the opportunity to avoid transvenous hardware among patients with tricuspid valve prostheses. We present the first case of a helix-based fixation leadless pacemaker implanted through valve-in-valve tricuspid prostheses in a 43-year-old female with extensive prior cardiac history. At the time of presentation, epicardial pacing was no longer a viable option in the setting of pacemaker dependence. Placement of a helix-fixed, leadless right ventricular pacemaker was performed as a bridge to dual-chamber leadless pacing. This was safely and effectively performed and highlighted favorable procedural characteristics that included RV cavity dimensions and prosthesis type. |
---|---|