Learning curve of dynamic navigation-assisted zygomatic implant surgery: An in vitro study
Dynamic computer-assisted zygomatic implant surgery (dCAZIS) has been reported to provide clinical efficacy with high accuracy and low risk of complications. However, the learning curve before performing dCAZIS effectively is unknown. The purpose of this in vitro study was to explore the learning cu...
Gespeichert in:
Veröffentlicht in: | The Journal of prosthetic dentistry 2024-07, Vol.132 (1), p.178.e1-178.e12 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Dynamic computer-assisted zygomatic implant surgery (dCAZIS) has been reported to provide clinical efficacy with high accuracy and low risk of complications. However, the learning curve before performing dCAZIS effectively is unknown.
The purpose of this in vitro study was to explore the learning curve of dCAZIS in dentists with different levels of experience in implant dentistry and navigation surgery.
Six senior dental students were randomly divided into 3 groups for initial training (FH-CI group: pretraining on freehand conventional implant surgery; FH-ZI group: pretraining on freehand ZI surgery; DN-CI group: pretraining on conventional implant surgery under dynamic navigation). Then, every operator conducted 6 repeated dCAZIS training sessions on edentulous 3-dimensional (3D) printed skull models and was asked to complete a self-report questionnaire after each training session. A total of 36 postoperative cone beam computed tomography (CBCT) scans with 144 ZI osteotomy site preparations were obtained and superimposed over the preoperative design for accuracy measurements. The operation time, 3D deviations, and results of the self-reports were recorded. Comparisons among groups were analyzed with independent-sample Kruskal–Wallis tests (α=.05), and correlations between study outcomes and the number of practices were calculated.
Operator experience and increased practice times did not significantly affect the accuracy of dCAZIS (P>.05). However, the operation time varied among groups (P |
---|---|
ISSN: | 0022-3913 1097-6841 1097-6841 |
DOI: | 10.1016/j.prosdent.2024.03.037 |