Robot-Assisted Hysterectomy Using the Double-Bipolar Method

To demonstrate the efficacy of the double-bipolar method in a benign hysterectomy. Stepwise demonstration of the technique with a narrative video. The double-bipolar method was first reported in 2011 [1] and is gaining popularity in Japan; however, its usefulness in robot-assisted hysterectomy is un...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of minimally invasive gynecology 2024-08, Vol.31 (8), p.640-640
Hauptverfasser: Ochi, Yoshifumi, Andou, Masaaki, Taniguchi, Ryou, Masuda, Sayaka, Sawada, Mari, Kanno, Kiyoshi, Sakate, Shintaro, Yanai, Shiori
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To demonstrate the efficacy of the double-bipolar method in a benign hysterectomy. Stepwise demonstration of the technique with a narrative video. The double-bipolar method was first reported in 2011 [1] and is gaining popularity in Japan; however, its usefulness in robot-assisted hysterectomy is under-reported. When unexpected bleeding occurs during robot-assisted hysterectomy using a monopolar technique, corrective measures may be prolonged and often require changing forceps. The Maryland forceps have 4 functions, including incision, dissection, grasping, and coagulation, which enable rapid responses to bleeding and reduce forceps changes and cost. Previously, we reported the usefulness of the double-bipolar technique in other surgical procedures [2,3]. Herein, we present a case of robot-assisted hysterectomy using this technique at an urban general hospital, including detailed insights into its execution. A 45-year-old female patient presented to our hospital with painful menstrual bleeding. Magnetic resonance imaging revealed an 8-cm myoma in the posterior wall of the uterine cervix. Consequently, a robot-assisted hysterectomy was performed using right-handed Maryland forceps (Intuitive, Sunnyvale, CA) and the ForceTriadTM Energy Platform (Medtronic, Minneapolis, MN) in the macro mode, with an output of 60 W. This configuration ensured a consistent electronic output, regardless of the electrical resistivity of the target tissues, facilitating precise incisions using a momentary high voltage [4]. The surgical duration was 60 minutes, and the estimated blood loss was 5 mL. The highly versatile double-bipolar method uses one forceps for incision, dissection, coagulation, and grasping and is useful in gynecological surgery. [Display omitted]
ISSN:1553-4650
1553-4669
1553-4669
DOI:10.1016/j.jmig.2024.03.013