Application of the (Hg,Re)-1223 ceramic on superconducting fault current limiter
We have investigated a small resistive SFCL device based on Hg 0.8Re 0.2Ba 2Ca 2Cu 3O 8+ δ , (Hg,Re)-1223, ceramic in order to obtain in the future a SFCL prototype for protecting a low impedance and high current system. Our initial study has shown that a fault current of 1.55 × 10 2 A peak/cm 2 at...
Gespeichert in:
Veröffentlicht in: | Physica. C, Superconductivity Superconductivity, 2007-09, Vol.460 (2), p.1451-1452 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We have investigated a small resistive SFCL device based on Hg
0.8Re
0.2Ba
2Ca
2Cu
3O
8+
δ
, (Hg,Re)-1223, ceramic in order to obtain in the future a SFCL prototype for protecting a low impedance and high current system. Our initial study has shown that a fault current of 1.55
×
10
2 A
peak/cm
2 at 60
Hz was reduced to 0.82
×
10
2 A
peak/cm
2, that is, the device limited the current at 59% without any damage on the (Hg,Re)-1223 superconductor in this range of current. It was observed that the device immediately recovered the initial conditions after that the fault current event is finished without any damage. |
---|---|
ISSN: | 0921-4534 1873-2143 |
DOI: | 10.1016/j.physc.2007.04.148 |