Service Life Estimation of Concrete Structures Reinforced with Cr-bearing Rebars under Macrocell Corrosion Conditions Induced by Cracking in Cover Concrete
Cracked concrete members reinforced with Cr-bearing rebars were assumed for the purpose of developing Cr-bearing rebars having the required corrosion resistance in macrocell corrosion environments induced by cracking in cover concrete. The service life of concrete structures reinforced with Cr-beari...
Gespeichert in:
Veröffentlicht in: | ISIJ International 2007, Vol.47(6), pp.875-882 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Cracked concrete members reinforced with Cr-bearing rebars were assumed for the purpose of developing Cr-bearing rebars having the required corrosion resistance in macrocell corrosion environments induced by cracking in cover concrete. The service life of concrete structures reinforced with Cr-bearing rebars was then estimated based on a macrocell corrosion rate model, and their Cr content to achieve a service life of 100 years was calculated. As a result, the service life of concrete reinforced with Cr-bearing rebars was found to increase as their Cr content increased regardless of the corrosive environment type. The calculation also revealed that Cr contents of 16% or more and 13% or more would lead to a service life of over 100 years in harsh and moderate chloride attack zones, respectively. In a carbonation zone, the Cr content to achieve a service life of over 100 years was calculated to be 9% or more. |
---|---|
ISSN: | 0915-1559 1347-5460 |
DOI: | 10.2355/isijinternational.47.875 |