Newly-Developed Adaptive Noise Absorption Control Technology for High Speed Fan Noise Reduction

The paper describes about a newly-developed adaptive noise absorption control (AAC) technology I for fan noise reduction and about proof test results of the technology. The AAC technology adaptively controls the reactance part of acoustic impedance of duct liners with mobile reflective plates and la...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JSME International Journal Series C Mechanical Systems, Machine Elements and Manufacturing Machine Elements and Manufacturing, 2006, Vol.49(3), pp.703-712
Hauptverfasser: KOBAYASHI, Hiroshi, KOH, Masaharu, OZAKI, Shunichi, YOKOCHI, Makoto, SATO, Takuo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The paper describes about a newly-developed adaptive noise absorption control (AAC) technology I for fan noise reduction and about proof test results of the technology. The AAC technology adaptively controls the reactance part of acoustic impedance of duct liners with mobile reflective plates and large acoustic chambers, absorbs fan tones and broadband noise together, and achieves larger overall fan noise reduction over a wide fan speed range. For actual proof of the technology, adaptive duct liner I was made on trial basis and was examined. The test result clarifies that the duct liner I could reduce fan noise larger than O.A. SPL 10dB (A) at max fan speed of 6000rpm, including reduction of low frequency noise and fundamental BPF tone and harmonics of 18dB at maximum. In response to fan speed change, the reflective plate movement control could achieve the large peak frequency shift and peak level increase in the acoustic absorption spectra, and could reduce fan noise larger than O.A. SPL 9dB (A) over the fan speed range from 1000 to 6000rpm.
ISSN:1344-7653
1347-538X
0914-8825
DOI:10.1299/jsmec.49.703