UV disinfection of wastewater coagulated with ferric chloride: Recalcitrance and fouling problems
Collimated beam and pilot tests using low pressure or medium pressure UV lamps were conducted to assess the disinfection performance of a municipal wastewater which had been pretreated by ferric chloride coagulation followed by sedimentation. The feed to the UV systems contained high levels of Fe (o...
Gespeichert in:
Veröffentlicht in: | Water science and technology 1998, Vol.38 (3), p.15-23 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Collimated beam and pilot tests using low pressure or medium pressure UV lamps were conducted to assess the disinfection performance of a municipal wastewater which had been pretreated by ferric chloride coagulation followed by sedimentation. The feed to the UV systems contained high levels of Fe (often above 3 mg/l); suspended solids and UV254 transmission values were also not ideal (mean approximately 30 mg/l and 32% respectively). The collimated beam tests indicated that the target level of 2,500 coliform forming units/100 ml often could not be reached, and the pilot tests revealed significant fouling after only a few hours. Thus physicochemical effluents of this nature likely require upstream filtration (or a relaxation of the target level) and a continual, automated cleaning system to ensure that performance levels can be maintained. |
---|---|
ISSN: | 0273-1223 1996-9732 |
DOI: | 10.1016/S0273-1223(98)00447-8 |