Preparation and Standardization of Method for Valuable Metals Analysis in Seawaters
A direct analytical technique was developed and tested for correct estimation of recovery of Eco-elements such as Li, B, Br, in the seawater, and three processed seawaters from Hanjoo Co. Ltd. The reliability of recovery technique and the correct estimation of total recoveries become a major interes...
Gespeichert in:
Veröffentlicht in: | Materials science forum 2007-05, Vol.544-545, p.593-596 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A direct analytical technique was developed and tested for correct estimation of
recovery of Eco-elements such as Li, B, Br, in the seawater, and three processed
seawaters from Hanjoo Co. Ltd. The reliability of recovery technique and the correct
estimation of total recoveries become a major interest before the launch of pilot plant.
High matrix solutions are frequently affected in analyte response during instrumental
analysis as the concentration of major component changed drastically. To overcome
such a complication during standard sample preparation and a better application in pilot
plant, a modified matrix matching standard addition method was developed and the
reliability was checked. The detection limit of elements in several seawaters analyzed
by applying the modified matrix matching standard addition method were 0.144 –
0.258-g/dm3 for lithium, 0.0.013 – 0.18mg/dm3 for boron, and 4.23 – 17.8mg/dm3 for
bromine. The instrumental analysis was carried by AAS for lithium and ICP-AES for
boron and bromine. |
---|---|
ISSN: | 0255-5476 1662-9752 1662-9752 |
DOI: | 10.4028/www.scientific.net/MSF.544-545.593 |