Measurements of heat transfer of multi-layered wall construction with foam gypsum
A new wall structure and its manufacturing technique have been developed. With this technique an experimental wall fragment has been manufactured. It consists of the following layers: internal finishing layer (gypsum boards and vapour insulation), foam gypsum, thermal insulation (polystyrene) and a...
Gespeichert in:
Veröffentlicht in: | Applied thermal engineering 2007-05, Vol.27 (7), p.1219-1224 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A new wall structure and its manufacturing technique have been developed. With this technique an experimental wall fragment has been manufactured. It consists of the following layers: internal finishing layer (gypsum boards and vapour insulation), foam gypsum, thermal insulation (polystyrene) and a plaster outer layer. The heat transfer coefficient through the given wall has been determined. The construction element’s heat transfer coefficient (
U) was determined by applying specially developed equipment and software. According to the experimental test, the coefficient’s
U value for the multi-layer construction with the foam polystyrene thermal insulation is 0.36
±
0.10
W/m
2
K. |
---|---|
ISSN: | 1359-4311 |
DOI: | 10.1016/j.applthermaleng.2006.02.047 |