ECG Changes Post-pericardiocentesis for Cardiac Tamponade Secondary to Non-small Cell Carcinoma of the Lung
Electrical alternans on electrocardiograph (ECG) is an uncommon but nearly pathognomonic sign of cardiac tamponade. Here, we present a male quadragenarian who came to the emergency department complaining of low back and right upper abdominal pain. Work-up revealed a large pericardial effusion associ...
Gespeichert in:
Veröffentlicht in: | Cureus 2024, Vol.16 (2), p.e54677-e54677 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Report |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Electrical alternans on electrocardiograph (ECG) is an uncommon but nearly pathognomonic sign of cardiac tamponade. Here, we present a male quadragenarian who came to the emergency department complaining of low back and right upper abdominal pain. Work-up revealed a large pericardial effusion associated with electrical alternans on ECG and clinical findings of cardiac tamponade. Pericardiocentesis drained approximately 1 liter of hemorrhagic fluid with resolution of cardiac tamponade and normalization of the ECG. Further evaluation with right hilar lymph node biopsy confirmed a diagnosis of poorly differentiated non-small cell adenocarcinoma of the lung. |
---|---|