Hydrogen Peroxide Sensor Based on Horseradish Peroxide (HRP) Immobilized PANI Electrode with Au Nanoparticles
In order to prepare the enzyme electrode for sensing of chemical molecules, the Au was coated on the surface of PP film by sputter coater. Polyaniline (PANI) was polymerized on the surface of the coated Au film by electrochemical polymerization of aniline in order to use working electrode. Subsequen...
Gespeichert in:
Veröffentlicht in: | Key engineering materials 2007-07, Vol.342-343, p.865-868 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In order to prepare the enzyme electrode for sensing of chemical molecules, the Au was
coated on the surface of PP film by sputter coater. Polyaniline (PANI) was polymerized on the
surface of the coated Au film by electrochemical polymerization of aniline in order to use working
electrode. Subsequently, horseradish peroxide (HRP) was immobilized on PANI electrode as
follows: Method I. The HRP was immobilized on the surface of PANI electrode by using Au
nanoparticle as linker (physical adsorption). Method II. The HRP was immobilized on the surface of
PANI electrode by using 2-aminothiophenol and Au nanoparticle as linker (Self-assembling
immobilization). Method III. HRP was directly immobilized with PANI electrode by using glutaric
dialdehyde as linker (covalent bonding). The sensing efficiency of the prepared HRP-PANI
electrode was also examined. The sensing efficiency of the HRP-PANI electrode for H2O2 was as
following order; Method I > Method III > Method II.. |
---|---|
ISSN: | 1013-9826 1662-9795 1662-9795 |
DOI: | 10.4028/www.scientific.net/KEM.342-343.865 |