Minimization of sludge production in biological processes: an alternative solution for the problem of sludge disposal

A combined system associating activated sludge and ozonation was evaluated for the treatment of urban wastewater. Experiments have shown that 70% reduction in sludge production can be reached (compared to a reference system running in low loaded conditions Y(obs) = 0.28 g VSS.g COD(-1)) by applying...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Water science and technology 2002-01, Vol.46 (10), p.63-70
Hauptverfasser: Deleris, S, Geauge, V, Camacho, P, Debelletontaine, H, Paul, E
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A combined system associating activated sludge and ozonation was evaluated for the treatment of urban wastewater. Experiments have shown that 70% reduction in sludge production can be reached (compared to a reference system running in low loaded conditions Y(obs) = 0.28 g VSS.g COD(-1)) by applying an ozone dosage of 0.05 g O3/g VSS(treated) Recycling of the ozonated sludge to the aeration tank induces a slight increase in effluent COD, but the biological treatment performance is maintained. Nitrification capabilities are not altered by the sludge reduction process and active biomass measurements revealed that autotrophic biomass seems to be less affected than the heterotrophs. Significant improvements in sludge settling characteristics are observed.
ISSN:0273-1223
1996-9732
DOI:10.2166/wst.2002.0291