The HW resonators in Jülich

Within the design of a new injector for the cooler synchrotron COSY, a linac option based on pulsed superconducting half-wave resonators (HWR) has been investigated. Two prototypes of the HWRs at 160 MHz were built by different manufacturers. We will present measurements for CW as well as pulsed ope...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physica. C, Superconductivity Superconductivity, 2006-07, Vol.441 (1), p.179-184
Hauptverfasser: Stassen, R., Eichhorn, R., Esser, F.M., Laatsch, B., Schug, G., Singer, H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Within the design of a new injector for the cooler synchrotron COSY, a linac option based on pulsed superconducting half-wave resonators (HWR) has been investigated. Two prototypes of the HWRs at 160 MHz were built by different manufacturers. We will present measurements for CW as well as pulsed operation to characterize RF performance and mechanical behavior of the two cavities. Whereas the slight differences in fabrication did not affect the electromagnetic results, the mechanical properties (mechanical eigenresonances, Lorentz-force detuning) significantly differed. To operate the cavities, ancillary systems (coupler, tuner, RF control) were designed and tested; the results of those will be summarized.
ISSN:0921-4534
1873-2143