Lung and diaphragm ultrasound as predictors of successful weaning from nasal continuous positive airway pressure in preterm infants

Objective Assessment of the utility of lung and diaphragm ultrasound in the prediction of successful weaning from nasal continuous positive airway pressure (NCPAP) in preterm infants. Study Design This prospective cohort study was conducted on preterm infants who were considered ready for weaning of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pediatric pulmonology 2024-05, Vol.59 (5), p.1428-1437
Hauptverfasser: Nour, Basma Ahmed, El‐Rahman, Ashraf Mohamed Abd, Hameed, Suzy Abd Elmabood Abd El, Mohsen, Nada, Mohamed, Adel, El‐Bayoumi, Mohammed Attia, Abdel‐Hady, Hesham Elsayed
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective Assessment of the utility of lung and diaphragm ultrasound in the prediction of successful weaning from nasal continuous positive airway pressure (NCPAP) in preterm infants. Study Design This prospective cohort study was conducted on preterm infants who were considered ready for weaning off NCPAP. Lung and diaphragm ultrasound were performed just before and 3 h after weaning off NCPAP. The primary outcome was to evaluate the accuracy of lung ultrasound (LUS) in predicting successful weaning from NCPAP. Results Out of 65 enrolled preterm infants, 30 (46.2%) were successfully weaned from NCPAP to room air. The successful weaning group had higher gestational ages, lower incidences of previous invasive mechanical ventilation, and treated hemodynamically significant patent ductus arteriosus before the trial weaning. A LUS score of ≤6, measured before discontinuation of NCPAP, exhibited a predictive sensitivity of 80% and specificity of 75% for successful weaning (Area under the curve (AUC) = 0.865,  ≤.001). When the LUS score was assessed 3 h after weaning from NCPAP, a cutoff point of ≤7 predicted successful weaning with a sensitivity and specificity of 90% and 60% respectively (AUC = 0.838, p ≤ .001). The diaphragmatic thickness fraction (DTF) was significantly lower in the successful weaning group. After adjustment for various factors, LUS score remained the only independent predictor of successful weaning. Conclusion LUS score before weaning from NCPAP has a good sensitivity and specificity for predicting successful weaning from NCPAP in preterm infants. Diaphragmatic excursion and DTF were not good predictors.
ISSN:8755-6863
1099-0496
DOI:10.1002/ppul.26933