Comparison of time-efficiency of individually wrapped screws and sterile screw racks in distal radius fracture treatment
Introduction Time-efficiency of individually wrapped screws versus screws in a screw rack is not well established. Materials and methods We performed a prospective single-center clinical study timing the interval between the surgeon asking and receiving a screw during plate and screw osteosynthesis...
Gespeichert in:
Veröffentlicht in: | Archives of orthopaedic and trauma surgery 2024-05, Vol.144 (5), p.2127-2129 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction
Time-efficiency of individually wrapped screws versus screws in a screw rack is not well established.
Materials and methods
We performed a prospective single-center clinical study timing the interval between the surgeon asking and receiving a screw during plate and screw osteosynthesis of distal radius fractures. Patients were randomized for individually wrapped screws or screws in a screw rack. The study was conducted in a Level 1 Trauma Center and surgeries were performed between March and June 2023.
Results
Average handling time for screws from a screw rack was 9 s (SD 5.5; range 3–28) and 22 s for individually wrapped screws (SD 6.1; range 6–38). This average difference of 13 s is significant (
p
< 0.0001).
Conclusion
There is a significant increase in handling time using individually wrapped screws over using a screw rack.
Level of evidence
Level I (therapeutic, randomized controlled trial). |
---|---|