A study of armature winding internal faults for turbogenerators

The internal fault of armature windings is one of the most severe faults for turbogenerators. It is necessary to know the transient currents of the machine when the internal faults occur so as to design suitable protection. Based on the multiloop method, a mathematical model of a turbogenerator with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industry applications 2002-05, Vol.38 (3), p.625-631
Hauptverfasser: Wang, Xiangheng, Chen, Songlin, Wang, Weijian, Sun, Yuguang, Xu, Longya
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The internal fault of armature windings is one of the most severe faults for turbogenerators. It is necessary to know the transient currents of the machine when the internal faults occur so as to design suitable protection. Based on the multiloop method, a mathematical model of a turbogenerator with internal faults is developed. The air-gap permeance analysis is used to calculate the parameters and eddy current of the solid rotor. The method is verified by computer simulation and experimental results. The developed model accurately predicts transient currents and provides theoretically insightful information for protecting turbogenerators with internal armature faults.
ISSN:0093-9994
1939-9367
DOI:10.1109/TIA.2002.1003410