Development of a coliforms monitoring system using an enzymatic fluorescence method

A coliforms monitoring system in treated effluent of a wastewater treatment plant has been developed. In order to achieve rapid monitoring within 1 hour, an enzymatic fluorescence method without a culturing process was introduced to this system. It converts the increase rate of fluorescence intensit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Water science and technology 2006-01, Vol.53 (4-5), p.523-532
Hauptverfasser: Morikawa, A, Hirashiki, I, Furukawa, S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A coliforms monitoring system in treated effluent of a wastewater treatment plant has been developed. In order to achieve rapid monitoring within 1 hour, an enzymatic fluorescence method without a culturing process was introduced to this system. It converts the increase rate of fluorescence intensity as enzymatic activity into the number of coliforms instead of converting fluorescence intensity itself. A flow injection analysis is used in this system for automatic measurement. Moreover, it is equipped with the pre-filtering unit to remove the interfering substances in the suspended solids causing deterioration in measurement precision. The good relationship (correlation coefficient of 0.90) between the obtained values using this system and the analysed values using the conventional direct counting method was observed in a test at an existing wastewater treatment plant.
ISSN:0273-1223
1996-9732
DOI:10.2166/wst.2006.156