Stability of a Cable Nicrosil-Nisil Thermocouple under Thermal Cycling
Experimental data on the stability of cable Nicrosil-Nisil thermocouples (type N) under step-by-step thermal cycling in the temperature range 20 to 1100 deg C and also under long-term heating in air at the temperature 1085 +/- 10 deg C are presented. The analysis of the influence of thermal cycling...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Experimental data on the stability of cable Nicrosil-Nisil thermocouples (type N) under step-by-step thermal cycling in the temperature range 20 to 1100 deg C and also under long-term heating in air at the temperature 1085 +/- 10 deg C are presented. The analysis of the influence of thermal cycling on thermal EMF drift is carried out. We conclude that N type thermocouples can be used as the reference thermocouple for the calibration of industrial base-metal thermocouples. |
---|---|
ISSN: | 0094-243X |
DOI: | 10.1063/1.1627167 |