Assembly and performance of hybrid-VRLA cells and batteries
Several commercial-grade hybrid-VRLA and AGM-VRLA cells and batteries have been assembled and tested under varying charge–discharge rates in a temperature range between 50 and −40 °C. Impedance studies on hybrid-VRLA and AGM-VRLA cells have been conducted to reflect on their resistive and capacitive...
Gespeichert in:
Veröffentlicht in: | Journal of power sources 2005-06, Vol.144 (2), p.560-567 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Several commercial-grade hybrid-VRLA and AGM-VRLA cells and batteries have been assembled and tested under varying charge–discharge rates in a temperature range between 50 and −40
°C. Impedance studies on hybrid-VRLA and AGM-VRLA cells have been conducted to reflect on their resistive and capacitive values. A linear relationship is found to exist between logarithmic state-of-charge values and ohmic impedance of batteries. In general, hybrid-VRLA cells and batteries perform better than their AGM-VRLA counterpart. A field-performance study conducted on AGM-VRLA and hybrid-VRLA batteries for solar-lighting application also suggests the latter to be superior. |
---|---|
ISSN: | 0378-7753 1873-2755 |
DOI: | 10.1016/j.jpowsour.2004.11.016 |