Arrhythmia detection using an implantable loop recorder after a negative electrophysiology study in Brugada syndrome: Observations from a multicenter international registry
Risk stratification in Brugada syndrome (BrS) remains controversial. In this respect, the role of the electrophysiology study (EPS) has been a subject of debate. In some centers, it is common practice to use an implantable loop recorder (ILR) after a negative EPS to help in risk stratification. Howe...
Gespeichert in:
Veröffentlicht in: | Heart rhythm 2024-08, Vol.21 (8), p.1317-1324 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Risk stratification in Brugada syndrome (BrS) remains controversial. In this respect, the role of the electrophysiology study (EPS) has been a subject of debate. In some centers, it is common practice to use an implantable loop recorder (ILR) after a negative EPS to help in risk stratification. However, the diagnostic value of this approach has never been specifically addressed.
The aim of this study was to describe the baseline characteristics and the main findings of a diagnostic workup strategy with an ILR after a negative EPS in BrS.
We conducted a retrospective international registry including patients with BrS and negative EPS (ie, noninducible ventricular tachycardia or ventricular fibrillation) before ILR monitoring.
The study included 65 patients from 8 referral hospitals in The Netherlands, Spain, and the United Kingdom (mean age, 39 ± 16 years; 72% male). The main indication for ILR monitoring was unexplained syncope/presyncope (66.2%). During a median follow-up of 39.0 months (Q1 25.0–Q3 47.6 months), 18 patients (27.7%) experienced 21 arrhythmic events (AEs). None of the patients died during follow-up. Bradyarrhythmias were the most common finding (47.6%), followed by atrial tachyarrhythmias (38.1%). Only 3 patients presented with ventricular arrhythmias. AEs were considered incidental in 12 patients (66.7%). In 11 patients (61.1%), AEs led to specific changes in treatment.
The use of ILR after a negative EPS in BrS is a safe strategy that reflected the high negative predictive value of EPS for ventricular arrhythmia in this syndrome. In addition, it allowed the detection of AEs in a significant proportion of patients, with therapeutic implications in most of them.
[Display omitted] |
---|---|
ISSN: | 1547-5271 1556-3871 1556-3871 |