Creep behavior of the ternary 95.5Sn-3.9Ag-0.6Cu solder: Part II: Aged condition

Compression creep tests were performed on the 95.5Sn-3.9Ag-0.6Cu (wt.%) solder. The specimens were aged prior to testing at 125°C, 24 h or 150°C, 24 h. Applied stresses were 2-40 MPa. Test temperatures were -25°C to 160°C. The 125°C, 24-h aging treatment caused the formation of coarsened Ag^sub 3^Sn...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of electronic materials 2004-12, Vol.33 (12), p.1473-1484
Hauptverfasser: VIANCO, Paul T, REJENT, Jerome A, KILGO, Alice C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Compression creep tests were performed on the 95.5Sn-3.9Ag-0.6Cu (wt.%) solder. The specimens were aged prior to testing at 125°C, 24 h or 150°C, 24 h. Applied stresses were 2-40 MPa. Test temperatures were -25°C to 160°C. The 125°C, 24-h aging treatment caused the formation of coarsened Ag^sub 3^Sn particle boundaries within the larger ternary-eutectic regions. The 150°C, 24-h aging treatment resulted in contiguous Ag^sub 3^Sn boundaries in the ternary-eutectic regions as well as a general coarsening of Ag^sub 3^Sn particles. The 125°C, 24-h aging treatment had only a small effect on the strain-time curves vis-à-vis the as-cast condition. Negative creep was observed at 75°C for time periods >10^sup 5^ sec and stresses of 3-10 MPa. The creep kinetics exhibited a sinh term (stress) exponent, p, of 5.3 ± 0.6 and an apparent-activation energy, ΔH, of 49 ± 5 kJ/mol when data from all test temperatures were included. A good data correlation was observed over the [-25-125°C] temperature regime. Steady-state creep kinetics exhibited a greater variability in the [125-160°C] regime because of the simultaneous coarsening of Ag^sub 3^Sn particles. The aging treatment of 150°C for 24 h resulted in a more consistent stress dependence and better reproducibility of the creep curves. Negative creep was observed in samples aged at 150°C for 24 h when tested at -25°C, 25°C, and 75°C. The values of p and ΔH were 4.9 ± 0.3 kJ/mol and 6 ± 5 kJ/mol, respectively. Only a slight improvement in the data correlation was observed when the analysis examined separated [-25-75°C] and [75-166°C] temperature regimes. Creep testing did not cause observable deformation in any of the sample microstructures. [PUBLICATION ABSTRACT] Key words: Tin-silver-copper (Sn-Ag-Cu) solder, constitutive model, reliability, creep
ISSN:0361-5235
1543-186X
DOI:10.1007/s11664-004-0089-7