Velocity Feedback with a Non-Collocated Pair of Sensor and Actuator for Tip Vibration Suppression of a Beam
This paper presents a theoretical and experimental study of a non-collocated pair of piezopolymer PVDF sensor and piezoceramic PZT actuator, which are bonded on a cantilever beam, in order to suppress unwanted vibration at the tip of the beam. The PZT actuator patch was bonded near the clamped part...
Gespeichert in:
Veröffentlicht in: | Key engineering materials 2006-01, Vol.321-323, p.200-203 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper presents a theoretical and experimental study of a non-collocated pair of
piezopolymer PVDF sensor and piezoceramic PZT actuator, which are bonded on a cantilever beam,
in order to suppress unwanted vibration at the tip of the beam. The PZT actuator patch was bonded
near the clamped part and the PVDF sensor, which was triangularly shaped, was bonded on the other
part of the beam. This is because the triangular PVDF sensor is known that it can detect the tip
velocity of a cantilever beam. Because the arrangement of the sensor and actuator pair is not
collocated and overlapped each other, the pair can avoid so called "in-plane coupling", which can be
found at a matched piezoelectric sensor and actuator pair and restricts the stability and performance of
direct velocity feedback control. The test beam is made of aluminum with the dimension of 200 × 20
× 2 mm. Before control, the sensor-actuator frequency response function is confirmed to have a nice
phase response without accumulation in a reasonable frequency range of up to 5000 Hz. The feedback
control attenuates the magnitude of the first two resonances in the error spectrum of about 6 -7 dB. |
---|---|
ISSN: | 1013-9826 1662-9795 1662-9795 |