Oblique lateral interbody fusion at L5-S1: feasibility, surgical approach window, incision line, and influencing factors
Purpose The primary aim of this study was to describe the feasibility, surgical approach window (SAW), and incision line (IL) for oblique lateral interbody fusion at L5-S1 (OLIF51) using computed tomography (CT). A secondary aim was to identify associations among approach characteristics and demogra...
Gespeichert in:
Veröffentlicht in: | European spine journal 2024-07, Vol.33 (7), p.2604-2610 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
The primary aim of this study was to describe the feasibility, surgical approach window (SAW), and incision line (IL) for oblique lateral interbody fusion at L5-S1 (OLIF51) using computed tomography (CT). A secondary aim was to identify associations among approach characteristics and demographic and anthropometric factors.
Methods
We performed a radiographic study of 50 male and 50 female subjects who received abdominal CT imaging. SAW was measured as the distance from the midline to the medial border of the iliac vessel. IL was measured at the skin surface corresponding to the distance between the center of the disc space and SAW lateral margin. OLIF51 feasibility was defined as the existence of at least a 1-cm SAW without retraction of soft tissues.
Results
For the left side, the OLIF51 SAW and IL were 12.1 ± 4.6 and 175.1 ± 55.3 mm. For the right side, these measures were 10.0 ± 4.3 and 185.0 ± 52.5 mm. Correlations of r = 0.648 (
p
|
---|---|
ISSN: | 0940-6719 1432-0932 1432-0932 |
DOI: | 10.1007/s00586-023-08017-4 |