Prediction and analysis of EOT signals due to tube defects near support plate in steam generator

In this paper, absolute and differential eddy current signals from various shapes and sizes of defects in the steam generator tube are numerically predicted and their slope characteristics are investigated. The signal variations due to frequency increase are also observed. Then, the analysis of mixe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Key engineering materials 2006-01, Vol.321-323, p.420-425
Hauptverfasser: Shin, Young-Kil, Song, Sung-Chul, Jung, Hee-Sung, Lee, Yun-Tai
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, absolute and differential eddy current signals from various shapes and sizes of defects in the steam generator tube are numerically predicted and their slope characteristics are investigated. The signal variations due to frequency increase are also observed. Then, the analysis of mixed defect signals affected by a ferromagnetic support plate is attempted. Axisymmetric finite element modeling is used for signal prediction and the slope angle of signal is used importantly in analyzing the signal. Results show that differential signals are useful for locating the position of a defect inside the support plate hole, while absolute signals are easy to presume and interpret even though the effect of support plate is mixed in the signal. Understanding of respective signal characteristics and relationship between them will be helpful for more reliable defect characterization.
ISSN:1013-9826