Absorption-based colorimetric detection of nickel(II) ion by phase separation of thermoresponsive magnetic nanoparticles under microflow
Therma-Max™ LSA Streptavidin is a thermoresponsive magnetic nanoparticle (TMNP). It can be introduced conveniently to molecular recognition groups by avidin–biotin interaction. In this study, we demonstrated the detection of nickel(II) ions by the magnetic separation of TMNP induced by their phase t...
Gespeichert in:
Veröffentlicht in: | Analytical sciences 2024-04, Vol.40 (4), p.791-798 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 798 |
---|---|
container_issue | 4 |
container_start_page | 791 |
container_title | Analytical sciences |
container_volume | 40 |
creator | Sasaki, Ren Inagawa, Arinori Xie, Xiaomao Ohnishi, Noriyuki Uehara, Nobuo |
description | Therma-Max™ LSA Streptavidin is a thermoresponsive magnetic nanoparticle (TMNP). It can be introduced conveniently to molecular recognition groups by avidin–biotin interaction. In this study, we demonstrated the detection of nickel(II) ions by the magnetic separation of TMNP induced by their phase transition under microflow. The NTA-tagged TMNP solution mixed with a Ni
2+
sample was introduced into a microchannel with a well structure. Moreover, the sample was heated to induce the thermally induced aggregation of TMNP. The Ni-capturing TMNP were trapped in the well by magnetic fields. The supernatant was removed from the outlet, and a dimethylglyoxime (DMG) solution was introduced into the device for colorimetric detection in the well. Because DMG has a higher stability constant with Ni
2+
, sensitive colorimetric detection of Ni
2+
can be achieved in devices where the sample volume, e.g., optical pathlength, is short. To demonstrate the feasibility of the proposed method, a recovery test was conducted using a commercially available cosmetic sample. Therein, complete collection was achieved.
Graphical abstract |
doi_str_mv | 10.1007/s44211-024-00521-x |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2930472970</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2930472970</sourcerecordid><originalsourceid>FETCH-LOGICAL-c391t-b72904f66ef5334ab3895078192b8ddf31c77f6036f2c89abe6794570217f743</originalsourceid><addsrcrecordid>eNp9kc1O3TAQha2qqFxoX6AL5CUsDOOfGydLhFq4EhIb9pbjjCE0sYOdUHgDHru-XGBZeWHL850z9hxCfnI45QD6LCslOGcgFANYC86ev5AVl6pmQqjqK1lBw4FVUsE-Ocj5AYCLWohvZF_W28XrFXk9b3NM09zHwFqbsaMuDjH1I86pd7TDGd22SKOnoXd_cDjebE7o9qZ9odN9kdCMk032g5rvMY0xYZ5iyP0T0tHeBZyLWbAhFrIcB8x0CR0mOvYuRT_Ev9_JnrdDxh_v-yG5_f3r9uKKXd9cbi7Or5mTDZ9Zq0UDylcV-rWUyraybtaga96Itu46L7nT2lcgKy9c3dgWK92otQbBtddKHpLjne2U4uOCeTZjnx0Ogw0Yl2xEI0GVHhoKKnZoeWHOCb2ZylxsejEczDYAswvAlADMWwDmuYiO3v2XdsTuU_Ix8QLIHZBLKdxhMg9xSaF8-X-2_wD5k5Pw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2930472970</pqid></control><display><type>article</type><title>Absorption-based colorimetric detection of nickel(II) ion by phase separation of thermoresponsive magnetic nanoparticles under microflow</title><source>Freely Accessible Japanese Titles</source><source>EZB-FREE-00999 freely available EZB journals</source><source>SpringerLink Journals - AutoHoldings</source><creator>Sasaki, Ren ; Inagawa, Arinori ; Xie, Xiaomao ; Ohnishi, Noriyuki ; Uehara, Nobuo</creator><creatorcontrib>Sasaki, Ren ; Inagawa, Arinori ; Xie, Xiaomao ; Ohnishi, Noriyuki ; Uehara, Nobuo</creatorcontrib><description>Therma-Max™ LSA Streptavidin is a thermoresponsive magnetic nanoparticle (TMNP). It can be introduced conveniently to molecular recognition groups by avidin–biotin interaction. In this study, we demonstrated the detection of nickel(II) ions by the magnetic separation of TMNP induced by their phase transition under microflow. The NTA-tagged TMNP solution mixed with a Ni
2+
sample was introduced into a microchannel with a well structure. Moreover, the sample was heated to induce the thermally induced aggregation of TMNP. The Ni-capturing TMNP were trapped in the well by magnetic fields. The supernatant was removed from the outlet, and a dimethylglyoxime (DMG) solution was introduced into the device for colorimetric detection in the well. Because DMG has a higher stability constant with Ni
2+
, sensitive colorimetric detection of Ni
2+
can be achieved in devices where the sample volume, e.g., optical pathlength, is short. To demonstrate the feasibility of the proposed method, a recovery test was conducted using a commercially available cosmetic sample. Therein, complete collection was achieved.
Graphical abstract</description><identifier>ISSN: 0910-6340</identifier><identifier>EISSN: 1348-2246</identifier><identifier>DOI: 10.1007/s44211-024-00521-x</identifier><identifier>PMID: 38383818</identifier><language>eng</language><publisher>Singapore: Springer Nature Singapore</publisher><subject>Advancements in Instrumentation ; Analytical Chemistry ; Chemistry ; Chemistry and Materials Science</subject><ispartof>Analytical sciences, 2024-04, Vol.40 (4), p.791-798</ispartof><rights>The Author(s), under exclusive licence to The Japan Society for Analytical Chemistry 2024. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><rights>2024. The Author(s), under exclusive licence to The Japan Society for Analytical Chemistry.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c391t-b72904f66ef5334ab3895078192b8ddf31c77f6036f2c89abe6794570217f743</citedby><cites>FETCH-LOGICAL-c391t-b72904f66ef5334ab3895078192b8ddf31c77f6036f2c89abe6794570217f743</cites><orcidid>0000-0003-0629-6060</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s44211-024-00521-x$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s44211-024-00521-x$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27923,27924,41487,42556,51318</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38383818$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sasaki, Ren</creatorcontrib><creatorcontrib>Inagawa, Arinori</creatorcontrib><creatorcontrib>Xie, Xiaomao</creatorcontrib><creatorcontrib>Ohnishi, Noriyuki</creatorcontrib><creatorcontrib>Uehara, Nobuo</creatorcontrib><title>Absorption-based colorimetric detection of nickel(II) ion by phase separation of thermoresponsive magnetic nanoparticles under microflow</title><title>Analytical sciences</title><addtitle>ANAL. SCI</addtitle><addtitle>Anal Sci</addtitle><description>Therma-Max™ LSA Streptavidin is a thermoresponsive magnetic nanoparticle (TMNP). It can be introduced conveniently to molecular recognition groups by avidin–biotin interaction. In this study, we demonstrated the detection of nickel(II) ions by the magnetic separation of TMNP induced by their phase transition under microflow. The NTA-tagged TMNP solution mixed with a Ni
2+
sample was introduced into a microchannel with a well structure. Moreover, the sample was heated to induce the thermally induced aggregation of TMNP. The Ni-capturing TMNP were trapped in the well by magnetic fields. The supernatant was removed from the outlet, and a dimethylglyoxime (DMG) solution was introduced into the device for colorimetric detection in the well. Because DMG has a higher stability constant with Ni
2+
, sensitive colorimetric detection of Ni
2+
can be achieved in devices where the sample volume, e.g., optical pathlength, is short. To demonstrate the feasibility of the proposed method, a recovery test was conducted using a commercially available cosmetic sample. Therein, complete collection was achieved.
Graphical abstract</description><subject>Advancements in Instrumentation</subject><subject>Analytical Chemistry</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><issn>0910-6340</issn><issn>1348-2246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kc1O3TAQha2qqFxoX6AL5CUsDOOfGydLhFq4EhIb9pbjjCE0sYOdUHgDHru-XGBZeWHL850z9hxCfnI45QD6LCslOGcgFANYC86ev5AVl6pmQqjqK1lBw4FVUsE-Ocj5AYCLWohvZF_W28XrFXk9b3NM09zHwFqbsaMuDjH1I86pd7TDGd22SKOnoXd_cDjebE7o9qZ9odN9kdCMk032g5rvMY0xYZ5iyP0T0tHeBZyLWbAhFrIcB8x0CR0mOvYuRT_Ev9_JnrdDxh_v-yG5_f3r9uKKXd9cbi7Or5mTDZ9Zq0UDylcV-rWUyraybtaga96Itu46L7nT2lcgKy9c3dgWK92otQbBtddKHpLjne2U4uOCeTZjnx0Ogw0Yl2xEI0GVHhoKKnZoeWHOCb2ZylxsejEczDYAswvAlADMWwDmuYiO3v2XdsTuU_Ix8QLIHZBLKdxhMg9xSaF8-X-2_wD5k5Pw</recordid><startdate>20240401</startdate><enddate>20240401</enddate><creator>Sasaki, Ren</creator><creator>Inagawa, Arinori</creator><creator>Xie, Xiaomao</creator><creator>Ohnishi, Noriyuki</creator><creator>Uehara, Nobuo</creator><general>Springer Nature Singapore</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0629-6060</orcidid></search><sort><creationdate>20240401</creationdate><title>Absorption-based colorimetric detection of nickel(II) ion by phase separation of thermoresponsive magnetic nanoparticles under microflow</title><author>Sasaki, Ren ; Inagawa, Arinori ; Xie, Xiaomao ; Ohnishi, Noriyuki ; Uehara, Nobuo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c391t-b72904f66ef5334ab3895078192b8ddf31c77f6036f2c89abe6794570217f743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Advancements in Instrumentation</topic><topic>Analytical Chemistry</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sasaki, Ren</creatorcontrib><creatorcontrib>Inagawa, Arinori</creatorcontrib><creatorcontrib>Xie, Xiaomao</creatorcontrib><creatorcontrib>Ohnishi, Noriyuki</creatorcontrib><creatorcontrib>Uehara, Nobuo</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sasaki, Ren</au><au>Inagawa, Arinori</au><au>Xie, Xiaomao</au><au>Ohnishi, Noriyuki</au><au>Uehara, Nobuo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Absorption-based colorimetric detection of nickel(II) ion by phase separation of thermoresponsive magnetic nanoparticles under microflow</atitle><jtitle>Analytical sciences</jtitle><stitle>ANAL. SCI</stitle><addtitle>Anal Sci</addtitle><date>2024-04-01</date><risdate>2024</risdate><volume>40</volume><issue>4</issue><spage>791</spage><epage>798</epage><pages>791-798</pages><issn>0910-6340</issn><eissn>1348-2246</eissn><abstract>Therma-Max™ LSA Streptavidin is a thermoresponsive magnetic nanoparticle (TMNP). It can be introduced conveniently to molecular recognition groups by avidin–biotin interaction. In this study, we demonstrated the detection of nickel(II) ions by the magnetic separation of TMNP induced by their phase transition under microflow. The NTA-tagged TMNP solution mixed with a Ni
2+
sample was introduced into a microchannel with a well structure. Moreover, the sample was heated to induce the thermally induced aggregation of TMNP. The Ni-capturing TMNP were trapped in the well by magnetic fields. The supernatant was removed from the outlet, and a dimethylglyoxime (DMG) solution was introduced into the device for colorimetric detection in the well. Because DMG has a higher stability constant with Ni
2+
, sensitive colorimetric detection of Ni
2+
can be achieved in devices where the sample volume, e.g., optical pathlength, is short. To demonstrate the feasibility of the proposed method, a recovery test was conducted using a commercially available cosmetic sample. Therein, complete collection was achieved.
Graphical abstract</abstract><cop>Singapore</cop><pub>Springer Nature Singapore</pub><pmid>38383818</pmid><doi>10.1007/s44211-024-00521-x</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0003-0629-6060</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0910-6340 |
ispartof | Analytical sciences, 2024-04, Vol.40 (4), p.791-798 |
issn | 0910-6340 1348-2246 |
language | eng |
recordid | cdi_proquest_miscellaneous_2930472970 |
source | Freely Accessible Japanese Titles; EZB-FREE-00999 freely available EZB journals; SpringerLink Journals - AutoHoldings |
subjects | Advancements in Instrumentation Analytical Chemistry Chemistry Chemistry and Materials Science |
title | Absorption-based colorimetric detection of nickel(II) ion by phase separation of thermoresponsive magnetic nanoparticles under microflow |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T12%3A57%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Absorption-based%20colorimetric%20detection%20of%20nickel(II)%20ion%20by%20phase%20separation%20of%20thermoresponsive%20magnetic%20nanoparticles%20under%20microflow&rft.jtitle=Analytical%20sciences&rft.au=Sasaki,%20Ren&rft.date=2024-04-01&rft.volume=40&rft.issue=4&rft.spage=791&rft.epage=798&rft.pages=791-798&rft.issn=0910-6340&rft.eissn=1348-2246&rft_id=info:doi/10.1007/s44211-024-00521-x&rft_dat=%3Cproquest_cross%3E2930472970%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2930472970&rft_id=info:pmid/38383818&rfr_iscdi=true |