Dextrose-containing fluids causing false-positive serum galactomannan: a case-control study and interrupted time series analysis
This study aimed to identify the cause of false-positive serum Aspergillus antigen galactomannan (GM) results in our centre. We performed a case-control study aiming to elucidate the factors associated with false-positive GM results. Independent risk factors for false-positive GM were evaluated thro...
Gespeichert in:
Veröffentlicht in: | Clinical microbiology and infection 2024-05, Vol.30 (5), p.682.e1-682.e4 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study aimed to identify the cause of false-positive serum Aspergillus antigen galactomannan (GM) results in our centre.
We performed a case-control study aiming to elucidate the factors associated with false-positive GM results. Independent risk factors for false-positive GM were evaluated through a multivariable regression analysis. An interrupted time series analysis was used to evaluate the effectiveness of an intervention removing the identified factors.
Among 568 patients tested, GM was positive in 130 patients of whom 97 had false-positive GM (cases). These were compared with 427 patients with true-negative GM (controls). Administration of dextrose-containing fluids within 6 days before GM testing was an independent predictor for false-positive GM results (adjusted odds ratio [aOR], 18.60; 95% CI, 8.95–38.66. An analysis of GM presence in different dextrose-containing fluids revealed positivity in 34.8% (8 of 23) (manufacturer A) and 33.3% (5 of 15) (manufacturer B) of the samples. Investigation of the manufacturing process revealed that the saccharification process employed enzymes derived from Aspergillus niger. After identifying the root cause of false positivity, GM-containing dextrose fluid use was restricted. Interrupted time series analysis showed an immediate reduction of GM false-positivity (−6.5% per week, p = 0.045) and a declining trend (−0.33% per week, p = 0.005) postintervention.
Administering dextrose-containing fluids was the primary factor causing false-positive serum Aspergillus antigen GM assay results. Our investigation led to a modification of the manufacturing process of the dextrose-containing fluids. |
---|---|
ISSN: | 1198-743X 1469-0691 |
DOI: | 10.1016/j.cmi.2024.01.019 |