Effect of nucleation site spacing on the pool boiling characteristics of a structured surface

Pool boiling characteristics of pyramidal shaped re-entrant cavities (characteristic size 40 μm) etched in silicon were evaluated in this study. A test surface was fabricated to totally eliminate back heat loss and minimize spreading in the substrate. The effect of inter-cavity spacing and convectio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of heat and mass transfer 2006-08, Vol.49 (17), p.2829-2839
Hauptverfasser: Nimkar, Nitesh D., Bhavnani, Sushil H., Jaeger, Richard C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Pool boiling characteristics of pyramidal shaped re-entrant cavities (characteristic size 40 μm) etched in silicon were evaluated in this study. A test surface was fabricated to totally eliminate back heat loss and minimize spreading in the substrate. The effect of inter-cavity spacing and convection plumes from a heat source located below the test surface on nucleate boiling parameters is documented. High speed photography was used to record and quantify the bubble departure frequency, the departure diameter, the active site density and to observe the effect of interaction between neighboring nucleation sites. Experiments were conducted in saturated FC 72 at atmospheric pressure.
ISSN:0017-9310
1879-2189