Failure analysis of welded joints in a power plant exhaust flue

In this paper, a series of failures of the welded joints in a power plant exhaust flue have been investigated. On-site investigation and experimental evaluations revealed that knife-line attack, embrittlement of weld metal detected due to sigma phase formation and thermal fatigue are responsible for...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Engineering failure analysis 2006-06, Vol.13 (4), p.527-536
Hauptverfasser: Jahromi, S.A. Jenabali, Javadpour, S., Gheisari, Kh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, a series of failures of the welded joints in a power plant exhaust flue have been investigated. On-site investigation and experimental evaluations revealed that knife-line attack, embrittlement of weld metal detected due to sigma phase formation and thermal fatigue are responsible for the failure. The flue is made of stabilized austenitic stainless steel (type 321) and works at 520–550 °C.
ISSN:1350-6307