Drift-controlled design of reinforced concrete frame structures under distant blast conditions—Part II: Implementation and evaluation
The model for the calculation of an equivalent static force (ESF) and the design procedure with ESF for single-degree-of-freedom (SDOF) systems presented in the first part of the two-part paper are extended into the design for a reinforced concrete (RC) frame structure under distant blast conditions...
Gespeichert in:
Veröffentlicht in: | International journal of impact engineering 2007-04, Vol.34 (4), p.755-770 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The model for the calculation of an equivalent static force (ESF) and the design procedure with ESF for single-degree-of-freedom (SDOF) systems presented in the first part of the two-part paper are extended into the design for a reinforced concrete (RC) frame structure under distant blast conditions. An empirical formula for the ESF factor involved in the ESF model is presented based on sample points obtained by comparing the nonlinear dynamic responses of frame structures under the blast loading with the corresponding nonlinear pushover analysis of the structure due to an ESF. The use of the method is demonstrated with two six-storey RC frame structures. Numerical verification of the method indicates that the maximum inter-storey drift ratios (MIDR) of the two designed frame structures in comparison to their respective targets are conservative to some extent. The reasons that may lead to the conservative designs are discussed. |
---|---|
ISSN: | 0734-743X 1879-3509 |
DOI: | 10.1016/j.ijimpeng.2006.01.009 |