Is preoperative 3D planning reliable for predicting postoperative clinical differences in range of motion between two stem designs in reverse shoulder arthroplasty
We aim to predict a clinical difference in the postoperative range of motion (RoM) between 2 reverse shoulder arthroplasty (RSA) stem designs (Inlay-155° and Onlay-145°) using preoperative planning software. We hypothesized that preoperative 3D planning could anticipate the differences in postoperat...
Gespeichert in:
Veröffentlicht in: | Journal of shoulder and elbow surgery 2024-08, Vol.33 (8), p.1771-1780 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We aim to predict a clinical difference in the postoperative range of motion (RoM) between 2 reverse shoulder arthroplasty (RSA) stem designs (Inlay-155° and Onlay-145°) using preoperative planning software. We hypothesized that preoperative 3D planning could anticipate the differences in postoperative clinical RoM between 2 humeral stem designs and by keeping the same glenoid implant.
Thirty-seven patients (14 men and 23 women, 76 ± 7 years) underwent a BIO-RSA (bony increased offset-RSA) with the use of preoperative planning and an intraoperative 3-dimensional-printed patient-specific guide for glenoid component implantation between January 2014 and September 2019 with a minimum follow-up of 2 years. Two types of humeral implants were used: Inlay with a 155° inclination (Inlay-155°) and Onlay with a 145°inclination (Onlay-145°). Glenoid implants remained unchanged. The postoperative RSA angle (inclination of the area in which the glenoid component of the RSA is implanted) and the lateralization shoulder angle were measured to confirm the good positioning of the glenoid implant and the global lateralization on postoperative X-rays. A correlation between simulated and clinical RoM was studied. Simulated and last follow-up active forward flexion (AFE), abduction, and external rotation (ER) were compared between the 2 types of implants.
No significant difference in RSA and lateralization shoulder angle was found between planned and postoperative radiological implants’ position. Clinical RoM at the last follow-up was always significantly different from simulated preoperative RoM. A low-to-moderate but significant correlation existed for AFE, abduction, and ER (r = 0.45, r = 0.47, and r = 0.57, respectively; P |
---|---|
ISSN: | 1058-2746 1532-6500 1532-6500 |
DOI: | 10.1016/j.jse.2023.11.031 |