Standoff Deep Ultraviolet Raman Spectrometer for Trace Detection
We developed a state-of-the-art, high-sensitivity, low-stray-light standoff deep-ultraviolet (DUV) Raman spectrometer for the trace detection of resonance Raman-enhanced chemical species. As an excitation source for Raman measurements, we utilized our recently developed, second-generation, miniaturi...
Gespeichert in:
Veröffentlicht in: | Applied spectroscopy 2024-02, Vol.78 (2), p.227-242 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We developed a state-of-the-art, high-sensitivity, low-stray-light standoff deep-ultraviolet (DUV) Raman spectrometer for the trace detection of resonance Raman-enhanced chemical species. As an excitation source for Raman measurements, we utilized our recently developed, second-generation, miniaturized, diode-pumped, solid-state neodymium-doped gadolinium orthovanadate (Nd:GdVO4) laser that generates quasi-continuous wave 228 nm light. This 228 nm excitation enhances the Raman intensities of vibrations of NOx groups in explosive molecules, aromatic groups in biological molecules, and various aromatic hydrocarbons. Our DUV Raman spectrograph utilizes a custom DUV f/8 Cassegrain telescope with an ∼200 mm diameter primary mirror, high-efficiency DUV transmission gratings, custom DUV mirrors, and a custom 228 nm Rayleigh rejection filter. We utilized our new standoff DUV Raman spectrometer to measure high signal-to-noise ratio spectra of ∼50 μg/cm2 drop-cast explosives: ammonium nitrate (AN), trinitrotoluene, pentaerythritol tetranitrate as well as aromatic biological molecules: lysozyme, tryptophan, tyrosine, deoxycytidine monophosphate, deoxyadenosine monophosphate at an ∼3 m distance within 10–30 s accumulation times. We roughly estimate the average ultraviolet resonance Raman (UVRR) detection limits for the relatively homogeneous drop-cast films of explosives and biological molecules to be ∼1 μg/cm2 when utilizing a continuous raster scanning that averages Raman signal over ∼1 cm2 sample area to avoid quick analyte depletion due to ultraviolet (UV) photolysis. We determined 3 m standoff UVRR detection limits for drop-cast AN films and identified factors impacting UVRR detection limits such as analyte photochemistry and analyte morphology. We found a detection limit of ∼0.5 μg/cm2 for drop-cast AN films on glass substrates when the Raman signal is averaged over ∼0.5 cm2 of sample surface using a continuous raster scan. For a step raster scan, when the probed sample area is limited to the laser spot size, the detection limit is approximately tenfold higher (∼5 μg/cm2) due to the impact of UV photochemistry.
Graphical abstract
This is a visual representation of the abstract. |
---|---|
ISSN: | 0003-7028 1943-3530 |
DOI: | 10.1177/00037028231217986 |