A High Precision Dynamic Autocollimator
In order to increase the precision of a high speed dynamic autocollimator, which uses quadrate detector, we propose a new method to compensate the residual measuring errors. For this purpose, a multi-tooth rotary table with precision of 0.2 seconds of arc is used to calibrate the autocollimator. Fro...
Gespeichert in:
Veröffentlicht in: | Key Engineering Materials 2005-01, Vol.295-296, p.337-342 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In order to increase the precision of a high speed dynamic autocollimator, which uses quadrate detector, we propose a new method to compensate the residual measuring errors. For this purpose, a multi-tooth rotary table with precision of 0.2 seconds of arc is used to calibrate the autocollimator. From the calibration data, a polynomial interpolation compensation algorithm is used. As a result, the measuring accuracy is increased to the order of 0.8 seconds of arc and the sampling speed is not affected. |
---|---|
ISSN: | 1013-9826 1662-9795 1662-9795 |
DOI: | 10.4028/www.scientific.net/KEM.295-296.337 |