Two-in-one sensor of refractive index and Raman scattering using hollow−core microstructured optical waveguides for colloid characterization

Hollow−core microstructured optical waveguides (HC−MOW) have recently emerged in sensing technologies, including the gas and liquid detection for industrial as well as clinical applications. Antiresonant HC−MOW provide capabilities for applications in refractive index (RI) sensing, while the long op...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Colloids and surfaces, B, Biointerfaces B, Biointerfaces, 2024-02, Vol.234, p.113705-113705, Article 113705
Hauptverfasser: Merdalimova, Anastasiia, Barmin, Roman, Vorobev, Viktor, Aleksandrov, Artem, Terentyeva, Daria, Estifeeva, Tatiana, Chernyshev, Vasiliy, German, Sergey, Maslov, Oleg, Skibina, Yulia, Rudakovskaya, Polina, Gorin, Dmitry
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Hollow−core microstructured optical waveguides (HC−MOW) have recently emerged in sensing technologies, including the gas and liquid detection for industrial as well as clinical applications. Antiresonant HC−MOW provide capabilities for applications in refractive index (RI) sensing, while the long optical path for analyte−light interaction in HC−MOW leads to increased sensitivity of sensor based on Raman scattering signal measurements. In this study, we developed a two−in−one sensor device using HC−MOW for RI and Raman scattering detection. The performance of the sensor was evaluated by characterizing protein−copolymer multicomponent colloids, specifically, bovine serum albumin (BSA) and poly(N − vinyl−2 −pyrrolidone−co−acrylic acid) P(VP−AA) nano−sized complexes and microbubbles of the corresponding shell. Monocomponent solutions showed linear dependencies of RI and characteristic Raman peak intensities on mass concentration. Multicomponent Raman sensing of BSA@P(VP−AA) complexes and microbubbles revealed that changes in P(VP−AA) characteristic peak intensities can describe interactions between components needed to produce colloid systems. RI sensing of multicomponent colloids demonstrated linear dependence on total mass concentrations for BSA@P(VP−AA) complexes, while corresponding BSA@P(VP−AA) microbubbles can be detected with concentrations as high as 4.0 × 108 MB/mL. Therefore, the developed two−in−one sensor of RI and Raman scattering can be used the robust characterization of albumin−based colloids designed for therapeutic and diagnostic needs. [Display omitted] •Two−in−one HC−MOW sensor of multispectral RI and Raman scattering was developed.•BSA@P(VP−AA) complexes and microbubbles were tested as multicomponent systems.•Changes in Raman spectra of multicomponent colloids can describe component interactions.•RI sensing of complexes demonstrated a linear dependence on mass concentrations.•RI of microbubbles can be detected with concentrations up to 4.0 × 108 MB/mL.
ISSN:0927-7765
1873-4367
DOI:10.1016/j.colsurfb.2023.113705