Utility of MRI in detection of PET-CT proven local recurrence of pancreatic adenocarcinoma after surgery
The aim of this prospective study was to investigate the accuracy and inter-observer reliability of MRI in detection of local recurrence (LR) of pancreatic adenocarcinoma (PAC) after surgery, which was proved by PET-CT and access correlation between functional MRI and PET parameters. Forty-five pati...
Gespeichert in:
Veröffentlicht in: | Medical oncology (Northwood, London, England) London, England), 2024-01, Vol.41 (2), p.47-47, Article 47 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this prospective study was to investigate the accuracy and inter-observer reliability of MRI in detection of local recurrence (LR) of pancreatic adenocarcinoma (PAC) after surgery, which was proved by PET-CT and access correlation between functional MRI and PET parameters. Forty-five patients who underwent PET-CT and MRI for follow-up purposes after radical operation of PAC were included. Twenty-three were PET positive (study group) and 22 negative for LR (control group). MR examination was performed within one month after PET-CT and three readers who were blind for PET-CT findings searched LR in T2W, 3D-dynamic post-contrast T1W-FS and DWI sequences, respectively. Sensitivity and specificity were calculated while inter-reader agreement was estimated by Cronbach’s Alpha reliability coefficient (CARC). Apparent diffusion coefficient (ADC) of LR was correlated with the size (maximal diameter) and functional PET-CT parameters: mean and maximum standardized uptake values (SUVmean, SUVmax), metabolic tumor volume (MTV) and total lesion glycolysis (TLG), using Spearman’s correlation coefficient (r
S
). Sensitivity and specificity among three readers in detecting the LR were 70% and 77–84% in T2W (CARC 0.806), 91–100% and 100% in 3D post-contrast T1W-FS (CARC 0.980), and both 100% in DWI sequences (CARC 1.000). Moderate inverse correlation was found between the ADC and SUVmean (
r
S
= − 0.484), MTV (
r
S
= − 0.494), TLG (
r
S
= − 0.519) and lesion size (
r
S
= − 0.567). MRI with DWI shows high diagnostic accuracy in detecting the LR of PAC in comparison to PET-CT as reference standard. ADC significantly inversely correlates with standard and advanced PET parameters and size of LR. |
---|---|
ISSN: | 1559-131X 1357-0560 1559-131X |
DOI: | 10.1007/s12032-023-02271-8 |