Augmenting Antimicrobial Resistance Surveillance: Rapid Detection of β‑Lactamase-Expressing Drug-Resistant Bacteria through Sensitized Luminescence on a Paper-Supported Hydrogel
The emergence of antimicrobial resistance (AMR) in pathogenic bacteria, expedited by the overuse and misuse of antibiotics, necessitates the development of a rapid and pan-territorially accessible diagnostic protocol for resistant bacterial infections, which would not only enable judicious prescript...
Gespeichert in:
Veröffentlicht in: | ACS sensors 2024-01, Vol.9 (1), p.351-360 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The emergence of antimicrobial resistance (AMR) in pathogenic bacteria, expedited by the overuse and misuse of antibiotics, necessitates the development of a rapid and pan-territorially accessible diagnostic protocol for resistant bacterial infections, which would not only enable judicious prescription of drugs, leading to infection control but also augment AMR surveillance. In this study, we introduce for the first time a “turn-on” terbium (Tb3+) photoluminescence assay supported on a paper-based platform for rapid point-of-care (POC) detection of β-lactamase (BL)-producing bacteria. We strategically conjugated biphenyl-4-carboxylic acid (BCA), a potent Tb3+ sensitizer, with cephalosporin to engineer a BL substrate CCS, where the energy transfer to terbium is arrested. However, BL, a major resistance element produced by bacteria resistant to β-lactam antibiotics, triggers a spontaneous release of BCA, empowering terbium sensitization within a supramolecular scaffold supported on paper. The remarkable optical response facilitates quick assessment with a binary answer, and the time-gated signal acquisition ensues improved sensitivity with a detection limit as low as 0.1 mU/mL. Furthermore, to ensure accessibility, particularly in resource-limited areas, we have developed an in loco imaging device as an affordable alternative to high-end instruments. The integration of the assay with the device readily identified the BL-associated drug-resistant strains in the mimic urinary tract infection samples within 2 h, demonstrating its excellent potential for in-field translation. We believe that this rapid paper-based POC assay, coupled with the in loco device, can be deployed anywhere, especially in developing regions, and will enable extensive surveillance on antibiotic-resistant infections. |
---|---|
ISSN: | 2379-3694 2379-3694 |
DOI: | 10.1021/acssensors.3c02065 |