Effectiveness of grease interceptors in food service establishments for controlling fat, oil and grease deposition in the sewer system

The water industry worldwide experiences numerous sewer blockages each year, partially attributed to the accumulation of fat, oil and grease (FOG). Managing this issue involves various strategies, including the requirement for installation of grease interceptors (GIs) installation. However, the clai...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Science of the total environment 2024-02, Vol.912, p.169441-169441, Article 169441
Hauptverfasser: Sultana, Nilufa, Roddick, Felicity, Jefferson, Bruce, Gao, Li, Bergmann, David, Papalois, Jim, Guo, Mike, Tzimourtas, Kyriakos, Pramanik, Biplob Kumar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The water industry worldwide experiences numerous sewer blockages each year, partially attributed to the accumulation of fat, oil and grease (FOG). Managing this issue involves various strategies, including the requirement for installation of grease interceptors (GIs) installation. However, the claimed efficacy of commercial GIs of eliminating 99 % of FOG has been questioned for many years because FOG deposit formation occurs despite food service establishments (FSEs) using GIs, therefore detailed understanding of FOG wastewater compositions and its removal by GIs is required. This study provides an insight into the key FOG components such as FOG particle size, metals and fatty acid (FA) profile in GI influent and effluent, and within the GI, at three different FSEs. Analysis of FAs identified substantial proportions of extra-long-chain FAs in the effluents, including arachidic (C20:0), behenic (C22:0), mead (C20:3), lignoceric (C24:0), and nervonic (C24:1) acids. In contrast, the household kitchen released palmitic (C16:0), oleic (C18:1) and linoleic (C18:2) acids. It was further observed that scums effectively remove the larger FOG particles, leaving only 10 % below 75.4 μm. Notably, FSEs which employed automatic dishwashers produced up to 80.4 % of particles ≤45 μm, whereas FSEs and household kitchen which used handwash sinks generated only 36.9 % and 26.3 % of particles ≤45 μm, respectively. This study demonstrated that the commercial GIs do not remove FOG entirely but clearly demonstrated that they discharge high concentrations of FOG with extra-long FFAs which were attributed to the occurrence of microbial activity and hydrolysis of triglycerides within the GI, potentially contributing to FOG deposition. [Display omitted] •Current commercial GIs do not completely remove FOG.•GIs release 12–64 times higher concentration of allowable FOG.•GIs release extra-long chain FAs.•Food service dishwashers produced up to 80 % particles
ISSN:0048-9697
1879-1026
DOI:10.1016/j.scitotenv.2023.169441