Radiation doses of medical radiation workers performing low-dose-rate brachytherapy with 198Au grains and 192Ir pins for patients with oral cancers
Objectives Low-dose-rate brachytherapy (LDR-BT) with 198 Au grains and 192 Ir pins is an essential treatment option for oral cancer due to its high rate of local control and low invasiveness. However, the radiation exposure of medical radiation workers is concerning. Thus, we aimed to determine the...
Gespeichert in:
Veröffentlicht in: | Oral radiology 2024-04, Vol.40 (2), p.234-241 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objectives
Low-dose-rate brachytherapy (LDR-BT) with
198
Au grains and
192
Ir pins is an essential treatment option for oral cancer due to its high rate of local control and low invasiveness. However, the radiation exposure of medical radiation workers is concerning. Thus, we aimed to determine the radiation dose delivered to medical radiation workers during LDR-BT using
198
Au grains and
192
Ir pins for oral cancer.
Methods
Thirty-two patients with oral cancer underwent
198
Au grain interstitial LDR-BT between June 2016 and May 2023, and 23 patients with tongue cancer underwent
192
Ir pin interstitial LDR-BT between March 2015 and November 2017 at our hospital. Dosimetry was performed by attaching a dosimeter to the chest pocket of the operator and assistant during
198
Au grain or
192
Ir pin LDR-BT. Since the operator also loads
198
Au grains into the implantation device, the operator’s radiation dose includes the dose received during this preparation.
Results
Mean radiation doses of the operators with
198
Au grain and
192
Ir pin LDR-BT were 165.8 and 211.2 μSv, respectively. Statistically significant differences between the radioactive sources of
198
Au grain and
192
Ir pin LDR-BT were observed (
p
= 0.0459). The mean radiation doses of the assistants with
198
Au grain and
192
Ir pin LDR-BT were 92.0 and 162.0 μSv, respectively. Statistically significant differences were observed between the radioactive sources of
198
Au grains and
192
Ir pin LDR-BT (
p
= 0.0003).
Conclusions
Regarding radioactive source differences,
192
Ir pin LDR-BT resulted in higher doses delivered to medical radiation workers than
198
Au grain LDR-BT. |
---|---|
ISSN: | 0911-6028 1613-9674 |
DOI: | 10.1007/s11282-023-00728-0 |