Radiation doses of medical radiation workers performing low-dose-rate brachytherapy with 198Au grains and 192Ir pins for patients with oral cancers

Objectives Low-dose-rate brachytherapy (LDR-BT) with 198 Au grains and 192 Ir pins is an essential treatment option for oral cancer due to its high rate of local control and low invasiveness. However, the radiation exposure of medical radiation workers is concerning. Thus, we aimed to determine the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Oral radiology 2024-04, Vol.40 (2), p.234-241
Hauptverfasser: Konishi, Masaru, Shimabukuro, Kiichi, Hirokawa, Junichi, Sadatoki, Takashi, Katsuta, Tsuyoshi, Imano, Nobuki, Nishibuchi, Ikuno, Murakami, Yuji, Kakimoto, Naoya
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives Low-dose-rate brachytherapy (LDR-BT) with 198 Au grains and 192 Ir pins is an essential treatment option for oral cancer due to its high rate of local control and low invasiveness. However, the radiation exposure of medical radiation workers is concerning. Thus, we aimed to determine the radiation dose delivered to medical radiation workers during LDR-BT using 198 Au grains and 192 Ir pins for oral cancer. Methods Thirty-two patients with oral cancer underwent 198 Au grain interstitial LDR-BT between June 2016 and May 2023, and 23 patients with tongue cancer underwent 192 Ir pin interstitial LDR-BT between March 2015 and November 2017 at our hospital. Dosimetry was performed by attaching a dosimeter to the chest pocket of the operator and assistant during 198 Au grain or 192 Ir pin LDR-BT. Since the operator also loads 198 Au grains into the implantation device, the operator’s radiation dose includes the dose received during this preparation. Results Mean radiation doses of the operators with 198 Au grain and 192 Ir pin LDR-BT were 165.8 and 211.2 μSv, respectively. Statistically significant differences between the radioactive sources of 198 Au grain and 192 Ir pin LDR-BT were observed ( p  = 0.0459). The mean radiation doses of the assistants with 198 Au grain and 192 Ir pin LDR-BT were 92.0 and 162.0 μSv, respectively. Statistically significant differences were observed between the radioactive sources of 198 Au grains and 192 Ir pin LDR-BT ( p  = 0.0003). Conclusions Regarding radioactive source differences, 192 Ir pin LDR-BT resulted in higher doses delivered to medical radiation workers than 198 Au grain LDR-BT.
ISSN:0911-6028
1613-9674
DOI:10.1007/s11282-023-00728-0