Diffusion spectrum imaging based semi-automatic optic radiation tractography for vision preservation in SEEG-guided radiofrequency thermocoagulation

To assess the efficacy and safety of stereoelectroencephalography (SEEG)-guided radiofrequency thermocoagulation (RFTC), using diffusion spectrum imaging (DSI) tractography to preoperatively delineate the optic radiation (OR) and reduce the risk of visual field defects (VFDs) where the epileptogenic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Seizure (London, England) England), 2024-01, Vol.114, p.61-69
Hauptverfasser: Song, Shiwei, Jean, Stéphane, Deng, Donghuo, Dai, Yihai, Fang, Xinrong, Wei, Xiaoqiang, Chen, Weitao, Shi, Songsheng, Jiang, Rifeng
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To assess the efficacy and safety of stereoelectroencephalography (SEEG)-guided radiofrequency thermocoagulation (RFTC), using diffusion spectrum imaging (DSI) tractography to preoperatively delineate the optic radiation (OR) and reduce the risk of visual field defects (VFDs) where the epileptogenic zones (EZs) are located in or close to the eloquent visual areas. We prospectively followed up twenty-four consecutive patients (12 males and 12 females) who underwent SEEG-guided RFTC in or near the OR pathway. A distance of ≥ 3.5 mm away from the OR on the targeted electrodes contacts that exhibited relevant ictal onset patterns, IEDs and EES during SEEG recordings, was required as our selection criterion prior to performing RFTC, enough to theoretically prevent VFDs. Using default tracking parameters, the optic radiation was tracked semi-automatically in DSI-studio. There were 12 male and 12 female patients ranging in age from 6 to 57 years, with follow-up period ranging from 6 to 37 months. Nineteen patients responded to RFTC (R+, 79.16 %), and 5 patients did not benefit from RFTC (R-, 20.83 %). The preoperative application of DSI semi-automatic based OR tractography was successful in the protection of the OR in all 24 patients. Three patients experienced a neurologic deficit following RFTC, and five patients had a partial quadrant visual field deficit prior to surgery that did not worsen, and none of the remaining nineteen patients had a quadrant visual field deficit. Our study validates the safety and efficacy of SEEG-RFTC as a viable therapeutic approach for epileptic foci situated in or adjacent to the visual eloquent regions. We demonstrate that DSI-based tractography offers superior precision in delineating the OR compared to DTI. We establish that implementing a criterion of a minimum distance of ≥ 3.5 mm in radius from the OR on the targeted electrode contacts prior to conducting RFTC can effectively mitigate the risk of VFDs.
ISSN:1059-1311
1532-2688
DOI:10.1016/j.seizure.2023.11.014