Effective ventilation and chest compressions during neonatal resuscitation - the role of the respiratory device
BACKGROUNDThe success of cardiopulmonary resuscitation (CPR) in newborns largely depends on effective lung ventilation; however, a direct randomized comparison using different available devices has not yet been performed.METHODSThirty-six professionals were exposed to a realistic newborn CPR scenari...
Gespeichert in:
Veröffentlicht in: | The journal of maternal-fetal & neonatal medicine 2023-12, Vol.36 (2), p.2276042-2276042 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | BACKGROUNDThe success of cardiopulmonary resuscitation (CPR) in newborns largely depends on effective lung ventilation; however, a direct randomized comparison using different available devices has not yet been performed.METHODSThirty-six professionals were exposed to a realistic newborn CPR scenario. Ventilation with either a bag-valve mask (BVM), T-piece, or ventilator was applied in a randomized manner during CPR using a Laerdal manikin. The primary outcome was the number of unimpaired inflations, defined as the peak of the inflation occurring after chest compression and lasting at least 0.35 s before the following chest compression takes place. The secondary outcomes were tidal volume delivered and heart compression rate. To simulate potential distractions, the entire scenario was performed with or without a quiz. Statistically, a mixed model assessing fixed effects for experience, profession, device, and distraction was used to analyze the data. For direct comparison, one-way ANOVA with Bonferroni's correction was applied.RESULTSThe number of unimpaired inflations was highest in health care professionals using the BVM with a mean ± standard deviation of 12.8 ± 2.8 (target: 15 within 30 s). However, the tidal volumes were too large in this group with a tidal volume of 42.5 ± 10.9 ml (target: 25-30 ml). The number of unimpaired breaths with the mechanical ventilator and the T-piece system were 11.6 (±3.6) and 10.1 (±3.7), respectively. Distraction did not change these outcomes, except for the significantly lower tidal volumes with the T-piece during the quiz.CONCLUSIONSIn summary, for our health care professionals, ventilation using the mechanical ventilator seemed to provide the best approach during CPR, especially in a population of preterm infants prone to volutrauma. |
---|---|
ISSN: | 1476-4954 |
DOI: | 10.1080/14767058.2023.2276042 |