Development, validation and clinical implementation of a UPLC-MS/MS bioanalytical method for simultaneous quantification of cabotegravir and rilpivirine E-isomer in human plasma

A reversed phase ultra-high performance liquid chromatography method was developed for the simultaneous quantification of cabotegravir (CAB) and the E-isomer of rilpivirine (RPV) in human EDTA plasma, also considering RPV E-isomer instability. Because of the instability of RPV (and CAB) in all light...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of pharmaceutical and biomedical analysis 2024-01, Vol.238, p.115832-115832, Article 115832
Hauptverfasser: Bevers, L.A.H., van Ewijk – Beneken Kolmer, E.W.J., Te Brake, L.H.M., Burger, D.M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A reversed phase ultra-high performance liquid chromatography method was developed for the simultaneous quantification of cabotegravir (CAB) and the E-isomer of rilpivirine (RPV) in human EDTA plasma, also considering RPV E-isomer instability. Because of the instability of RPV (and CAB) in all light conditions, the (RPV Z-isomer/total RPV)-isomer ratio of RPV was determined for each stock, calibration curve standard, quality control sample and patient sample. [2H3]-CAB and [13C6]-RPV were used as internal standard. Sample preparation involved protein precipitation of plasma using methanol. An HSS T3 column with a guard column (set at 40 °C) was used for analyte separation. The mobile phase components were 65 % 0.1 % formic acid in water (A) and 35 % 0.1 % formic acid in acetonitrile (B) and the flow rate was 0.5 mL/min. Detection was performed with tandem mass spectrometry (MS/MS) in a total runtime of 3.0 min. The assay was validated over the concentration range of 0.0500 – 10.0 mg/L for CAB and 0.00300 – 3.00 mg/L for RPV. The average within-day and between-day accuracies for the assay in plasma were 101 % and 101 % for CAB and 97.6 % and 98.5 % voor RPV, respectively. Within-day and between-day precision in coefficients of variations (CV) were 5.0 %. Extraction recovery was 99 % and 102 % for CAB and its internal standard and 95 % and 97 % for RPV and its internal standard. As our aim was that the (Z-isomer RPV/total RPV) response ratio in patient samples had to be less than 10 % to give reliable results, the (Z-isomer RPV/total RPV) response ratio in stocks, calibration curve standards and internal quality control samples were also taken into account being maximal 0.9 % and 2.3 % respectively. This assay has been successfully used in our Therapeutic Drug Monitoring (TDM) service for people living with HIV on long-acting injectable therapy with CAB/RPV and will also be used in future pharmacokinetic studies. •Cabotegravir and rilpivirine are drugs used in long-acting injectable therapy for people living with HIV.•This bioanalytical assay is able to analyze cabotegravir and both isomers of rilpivirine in human EDTA-plasma.•Light-protecting patient samples gives reliable results for Therapeutic Drug Monitoring and pharmacokinetic studies.•Results of the first TDM analyses in our laboratory were within the calibration ranges of the two compounds.
ISSN:0731-7085
1873-264X