A Study for L/D Determination of Filtered Neutron Beams Including Scattering Neutrons Component

Geometrical parameters (L/D, L and D values) are experimentally determined for a specially designed filtered-neutron beam (IR beam) implemented to HANARO in KAERI using a high precision L/D device. In spite of L agrees with the designed value, appreciable differences of D and then L/D were observed...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Key engineering materials 2004-01, Vol.270-273, p.1400-1405
Hauptverfasser: Watanabe, Shigeya, Satoh, Masanori, Lim, In Chul, Sim, Cheul Muu, Kobayashi, Hisao
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Geometrical parameters (L/D, L and D values) are experimentally determined for a specially designed filtered-neutron beam (IR beam) implemented to HANARO in KAERI using a high precision L/D device. In spite of L agrees with the designed value, appreciable differences of D and then L/D were observed between designed and experimental value. Discussions are made for the source of discrepancies taken into considering a beam pass deflection due to scattering effect in the filter system as well as the design of the IR beam collimator system.
ISSN:1013-9826
1662-9795
1662-9795
DOI:10.4028/www.scientific.net/KEM.270-273.1400