Accuracy of digital duplication scanning methods for complete dentures
Purpose To compare the accuracy of four digital scanning methods in duplicating a complete denture. Material and Methods Four scanning methods were used: cone beam computed tomography (CBCT), Straumann desktop scanner (DS), Trios intraoral scanner (TIO), and Virtuo Vivo intraoral scanner (VVIO). Eac...
Gespeichert in:
Veröffentlicht in: | Journal of prosthodontics 2025-01, Vol.34 (1), p.42-48 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
To compare the accuracy of four digital scanning methods in duplicating a complete denture.
Material and Methods
Four scanning methods were used: cone beam computed tomography (CBCT), Straumann desktop scanner (DS), Trios intraoral scanner (TIO), and Virtuo Vivo intraoral scanner (VVIO). Each method was used to duplicate all the surfaces of a printed complete denture. The denture was scanned 10 times in each group. The trueness (in root mean square, RMS) and precision (in standard deviation, SD) were calculated by comparing the combined dentition, denture extension, and intaglio surfaces with the reference file. One‐way analysis of variance and F‐tests were used to test statistical differences (α = 0.05).
Results
For the scanning accuracy of the whole denture, CBCT showed the highest RMS (0.249 ± 0.020 mm) and lowest trueness than DS (0.124 ± 0.014 mm p |
---|---|
ISSN: | 1059-941X 1532-849X 1532-849X |
DOI: | 10.1111/jopr.13788 |