Motor-Respiratory Coupling Improves Endurance Performance during Rhythmic Isometric Handgrip Exercise

This study aimed to evaluate whether motor-respiratory coupling exists in rhythmic isometric handgrip exercises and its effect on endurance performance. In addition, the mechanism underlying observed effects was to be investigated if higher motor-respiratory coupling rate could enhance endurance per...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medicine and science in sports and exercise 2024-03, Vol.56 (3), p.536-544
Hauptverfasser: Li, Zhibin, Li, Wei, Lin, Ping-Ju, Jia, Tianyu, Ji, Linhong, Li, Chong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study aimed to evaluate whether motor-respiratory coupling exists in rhythmic isometric handgrip exercises and its effect on endurance performance. In addition, the mechanism underlying observed effects was to be investigated if higher motor-respiratory coupling rate could enhance endurance performance. Eleven subjects completed three rhythmic isometric handgrip trials to task failure in a randomized manner. After one pretraining session to determine personal grip frequency, one trial was performed without respiration requirement (CON), and two trials were performed with inspiration-motor coupling (IMC) or expiration-motor coupling. Changes in maximal voluntary contraction (MVC) and EMG were used to measure neuromuscular fatigue. Force data during test were used to assess exercise intensity. Another 10 subjects completed electrical stimulation-induced finger flexion and extension during normal inspiration, normal expiration, fast inspiration, fast expiration, and breath holding. Force changes of different breathing conditions were compared. Normalized exercise time to exhaustion was significantly longer in IMC (1.27 ± 0.23) compared with expiration-motor coupling (0.82 ± 0.18) and CON (0.91 ± 0.18, P < 0.001). ΔMVC, grip frequency, force, and EMG indices were not different among conditions (all P > 0.05). Electrical stimulation-induced finger extensor force was significant higher during fast inspiration (1.11 ± 0.09) than normal respiration (1.00 ± 0.05) and fast expiration (0.94 ± 0.08, P < 0.05). IMC is an effective way to improve endurance performance of rhythmic handgrip exercise. This is likely due to a reduction in the energy consumption of motion control, as evidenced by similar peripheral fatigue in different conditions and modulation of corticospinal excitability by respiration.
ISSN:0195-9131
1530-0315
DOI:10.1249/MSS.0000000000003329