Real-Time Digital Feedback Device and Simulated Newborn Ventilation Quality
OBJECTIVES Effective bag-valve-mask ventilation is critical for reducing perinatal asphyxia-related neonatal deaths; however, providers often fail to achieve and maintain effective ventilation. The Augmented Infant Resuscitator (AIR) attaches to bag-valve-masks and provides visual feedback on air le...
Gespeichert in:
Veröffentlicht in: | Pediatrics (Evanston) 2023-11, Vol.152 (5), p.1 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | OBJECTIVES Effective bag-valve-mask ventilation is critical for reducing perinatal asphyxia-related neonatal deaths; however, providers often fail to achieve and maintain effective ventilation. The Augmented Infant Resuscitator (AIR) attaches to bag-valve-masks and provides visual feedback on air leaks, blocked airways, harsh breaths, and improper ventilatory rates. We evaluated the effect of this real-time-digital feedback on ventilation quality and the effective determination of airway integrity in a randomized controlled study in Uganda and the United States. METHODS Birth attendants trained in newborn resuscitation were randomized to receive either real-time AIR device feedback (intervention) or no feedback (control) during ventilation exercises. Intervention-arm participants received a 2-minute orientation on interpreting AIR feedback using a single-page iconography chart. All participants were randomly assigned to 3 blinded ventilation scenarios on identical-appearing manikins with airways that were either normal, significantly leaking air, or obstructed. RESULTS We enrolled 270 birth attendants: 77.8% from Uganda and 22.2% from the United States. Birth attendants receiving AIR feedback achieved effective ventilation 2.0 times faster: intervention mean 13.8s (95% confidence interval 10.6–17.1) versus 27.9s (21.6–34.3) for controls (P < .001). The duration of effective ventilation was 1.5 times longer: intervention mean 72.1s (66.7–77.5) versus 47.9s (41.6–54.2) for controls (P < .001). AIR feedback was associated with significantly more accurate and faster airway condition assessment (intervention mean 43.7s [40.5–47.0] versus 55.6s [51.6–59.6]). CONCLUSIONS Providers receiving real-time-digital AIR device feedback achieved effective ventilation significantly faster, maintained it longer, and determined airway condition faster and more accurately than providers in the control group. |
---|---|
ISSN: | 0031-4005 1098-4275 |
DOI: | 10.1542/peds.2022-060599 |